Generator runs, but no electricity?
Moderator: bfadmin
Generator runs, but no electricity?
Ok, feeling stupid about this. I started up the generator today to make sure it works ok. It started right up and fridge and the micro works. I switched on the AC. After a bit of normal delay I heard the AC kick on. Almost immediately, I heard a click in the area of the fuse panel/converter and no 110V electricity anywhere. The generator kept on running. I have checked all the circuit breakers by the converter. No fix. I can plug it into shore power and everything works fine. There must be some sort of circuit breaker somewhere else that connects the generator to the 110V system, right? What else am I missing. This is a 2005 26RSB
HELP! I am delivering it to the new owners next week.
Chris.
HELP! I am delivering it to the new owners next week.
Chris.
Go to Search, type in Generac Generator Problem and read all about it. I had the same problem along with a number of other Born Free owners which you will read about on the above post, got the new electronic transfer switch or whatever they call it from the converter mfg., installed it and all is well.
Still no juice
dsfriday,
My 26RSB is a 2005, not the newer ones that much discussions were posted about mechanical vs electronic switches. Plus, the electricity from the generator never came back on, even though it runs.
Funny thing is, we almost never use the generator nor the AC...:O(
My 26RSB is a 2005, not the newer ones that much discussions were posted about mechanical vs electronic switches. Plus, the electricity from the generator never came back on, even though it runs.
Funny thing is, we almost never use the generator nor the AC...:O(
There is a switch/breaker under the sink on some models that is a reset and the red button on it needs to be reset. This was covered on another post with a picture of the reset. It is sometimes located in another spot discussed in that post but I don't remember where. Mine did this and it was under the sink...everything else was OK and then someone pointed this out.
Steve,2001 26rsb
East tennessee
East tennessee
I had the same problem with my 06 and 07 and the transfer switch replacement solved it. I would call bornfree and ask on monday. If you want to test it you can take the input line off the generator and put a female adapter on it and then plug in your shore power cord. That will bypass the transfer switch altogether. IF it does not switch off then you have the same problem we all had earlier. They put an 18 amp switch in and it was not big enough.
2015 Royal Splendor on Ford 550 none slide version
Former owner 2007 24foot rear bath painted and 2006 22 foot built for two
Former owner 1994 34 foot 2000 36 foot and 2001 42 foot FORETRAVEL's.
Former owner 2007 24foot rear bath painted and 2006 22 foot built for two
Former owner 1994 34 foot 2000 36 foot and 2001 42 foot FORETRAVEL's.
-
- Posts: 338
- Joined: Mon Jan 07, 2008 5:30 pm
Bill Hemme, i hope my computer doesn't double post this and if it does, I apologize. It is not operator error. We have a 2004 RSB with a Generac and had the same problem. It was traced to a relay switch in the generator compartment that had somehow been switched to off. Generator ran, but did not power. No repair needed. Hope this helps.
Judy
Judy